跳转到主内容
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

VSC 为 VMware 所做的哪些设置要求重新引导 ESX 主机才能生效?

Views:
21
Visibility:
Public
Votes:
0
Category:
virtual-storage-console-for-vmware-vsphere
Specialty:
nfs
Last Updated:

适用于

FlexPod

解答

适用于 VMware 的虚拟存储控制台( VSC )具有一项功能、可以在与 VMware 注册的 vCenter 相连的任何或所有 ESX 主机上为 NetApp 建议的 NFS 、 MPIO 和 HBA 设置分配值。但是,要使某些 NFS 和 HBA 设置生效、必须重新引导 ESX 主机。

下面给出了设置。需要重新引导的设置用星号 (*) 标识。

NFS 设置

  • Net.TcpipHeapSize *   
  • Net.TcpipHeapMax *
  • NFS.MaxVolumes
  • NFS.HeartbeatMaxFailures
  • NFS.HeartbeatFrequency
  • NFS.HeartbeatTimeout

MPIO 设置

  • PSP changes:对于启用了 ALUA 的 ESX 4.0+ FC 路径,设置为 RR (循环)。对于所有其他配置,设置为 FIXED。
  • ALUA:在控制器上的 IGroup 中设置。ESX 将无法查看该信息、直到主机重新启动。

适配器设置

  • Disk.QFullSampleSize
  • Disk.QFullThreshold
  • Emulex FC HBA timeouts *
  • QLogic FC HBA timeouts *
  • QLogic iSCSI HBA timeouts *

其他信息

不适用

 

Scan to view the article on your device