跳转到主内容

为什么EMS报告"vifmgr.cluscheck.crcerrors"而未报告大量的总错误

Views:
30
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas
Last Updated:

适用场景

ONTAP

问题解答

  • 它与的数量无关 total error、但取决于错误是否超过总数据包的%阈值。
  • 默认情况下、CRC错误阈值设置为1000、这意味着、如果1000个(0.1%)数据包中有1个以上存在CRC错误、则运行状况监控器将通过EMS和/或ASUP进行通知

追加信息

不适用

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.