In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

NetApp KCS Award

为什么存储控制器上的 CRC 错误会随 LIF 的放置而发生?

Views:
17
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
network
Last Updated:

适用于

  • ONTAP
  • Cut-Through 交换机

解答

  • 如果交换机是直通端口、则在 ifstat 上发现的 CRC 错误可能与该端口与相应交换机端口之间的有效通信无关
  • 直通交换机会在完全接收帧之前转发帧、以减少存储和转发帧带来的延迟
  • 交换机会将包含 CRC 错误的帧转发到出站端口、从而导致交换机在完成接收之前开始转发帧
  • 当发生 CRC 错误时、将 LIF 移动到另一个端口将产生将这些数据包重定向到新端口的副作用
  • 这给人的印象是, CRC 错误 " 跟随 " 了新端口的 LIF

其他信息

  • 对 CRC 错误的起源进行故障排除取决于所使用的特定交换机型号和供应商
  • 请与交换机供应商联系以进行进一步调查

 