In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

使用 ESXi 7.0 部署 NetApp ONTAP FC-NVMe 有哪些要求?

Views:
73
Visibility:
Public
Votes:
0
Category:
data-ontap-8
Specialty:
virt
Last Updated:

适用于

  • ESXi 7.0 FC-NVMe
  • VMware vSphere 7.0
  • ONTAP

解答

VMware vSphere 7.0 版本包括对 FC-NVMe 存储堆栈的支持。

此 KB 描述了 ONTAP 与 ESXi 7.0 FC-NVMe 之间的互操作性改进所需的设置。

  1. 对于 Broadcom Emulex LPe3200x FCP HBA 、必须设置以下参数以检测 NVMe 命名空间:

    esxcli system module parameters set -m lpfc -p lpfc_enable_fc4_type=3

    重新引导系统以使设置生效。

   注: Broadcom LPe3500x HBA 不需要上述命令。

  1. ESXi 7.0 检测到命名空间并在从 ONTAP 中显示新的子系统后、 ESXi 7.0 将不会检测到显示的新命名空间。要检测新的子系统和命名空间、可以执行以下操作: 
     
    1. ONTAP 问题: vserver stop <vserver-name>, followed by vserver start <vserver-name>
    2. 对主机 HBA 或目标 LIF 执行链路重置

    注意:这会导致命名空间临时丢失和可能的应用程序中断,并应在计划维护窗口中执行。

  1. 为了提高互操作性,必须将以下参数设置为“ 0 ”:

    esxcfg-advcfg -s 0 /Misc/HppManageDegradedPaths

    注意:如果未将此值设置为“ 0 ”,将导致应用程序中断
     
    1. 重新引导系统。
    2. 检查配置是否已禁用并启动 test:

      esxcfg-advcfg -g /Misc/HppManageDegradedPaths

      abe上方 命令应将该值显示为 0->“Value of HppManageDegradedPaths is 0”
       
  2. 在命名空间上部署 Solaris VM 及其数据磁盘、确保仅使用虚拟 SCSI 控制器( LSI Logic SAS 、 PVSCSI )。不建议将虚拟 NVMe 控制器用于 Solaris VM 。
  3. NetApp 支持 FC SCSI LUN 和命名空间共存配置。有关 LUN 和命名空间的数量以及 VMware 建议的路径计数,请参见 VMware 文档。
  4. 对于部署在 SCSI 和 NVMe 命名空间上、并将虚拟 SCSI 控制器( LSI Logic SAS 、 PVSCSI )连接到 VM 的 VM 、建议磁盘超时为 60 秒。请咨询相应的 VM OS 供应商,了解如何将磁盘超时设置为 60 秒。
  5. 有关[1]任何未决问题和问题,请参阅 NetApp IMT 。