跳转到主内容

升级期间, AFF-A400 会在端口 E3A/e3b 上显示 netif.sfpNotSupported

Views:
13
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>端口关闭</a><a>2008668733I</a><a>BURT 1383080</a><a>离子系统</a>
Last Updated:

适用场景

  • ONTAP 9.7P14及更早的修补程序 版本
  • AF-A400
  • 1.0.1-E-31至1.0.1-E-39 固件上的100G以太网控制器(X1151)

问题描述

在ONTAP升级期间、 更新后的节点上的集群端口e3a和e3b会关闭、HA配对节点会停滞、等待交还。

  • 升级后的节点上的EMS报告SFP+/QSFP +不受支持的消息。

netif.sfpNotSupported: The SFP+ or QSFP+ module (not supported ) installed in e3a is not supported with this network interface.
netif.sfpNotSupported: The SFP+ or QSFP+ module (not supported ) installed in e3b is not supported with this network interface.

  • 升级后的节点显示端口已关闭。 ::> system node run -node updated_node -command sysconfig -a

    slot 3: Dual 100G Ethernet Controller IONIC
        e3a MAC Address:   00:ae:cd:09:b5:50 (auto-unknown-down)
          ...
        e3b MAC Address:   00:ae:cd:09:b5:51 (auto-unknown-down)
          ...
        Device Type:     ionic
        Firmware Version:   1.4.0-E-96
        Serial Number:    FPN0123456A

 

  • 未升级的节点显示端口已启动。 ::> system node run -node not_updated_node -command sysconfig -a 示例:  

    slot 3: 100G Ethernet Controller IONIC
        e3a MAC Address:   00:ae:cd:09:c0:30 (auto-100g_cr4-fd-up)
          ...
        e3b MAC Address:   00:ae:cd:09:c0:31 (auto-100g_cr4-fd-up)
          ...
        Device Type:     ionic
        Firmware Version:   1.0.1-E-31
        Serial Number:    FPN0123456B

  • 未升级节点的EMS报告链路错误: ::> event log show -event **NotSupported*

Tue Aug 03 16:06:15 +0300 [not_updated_node: kernel: netif.linkInfo:info]: Ethernet adapter e3b: Link Reset in progress.
Tue Aug 03 16:25:10 +0300 [not_updated_node: kernel: netif.linkInfo:info]: Ethernet adapter e3a: Link Reset in progress.


 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.