问题

  1. 系统运行状况已降级
cluster::>system health status show
Status
---------------
degraded
 
  1. 交换机运行状况子系统已降级
cluster::> system health subsystem show
Subsystem         Health
----------------- ------------------
SAS-connect       ok
Environment       ok
Memory            ok
Service-Processor ok
Switch-Health     degraded
CIFS-NDO          ok
Motherboard       ok
IO                ok
MetroCluster      ok
MetroCluster_Node ok
FHM-Switch        ok
FHM-Bridge        ok
SAS-connect_Cluster ok
13 entries were displayed.
 
  1. 将记录以下运行状况警报
cluster::> system health alert show
Node: node01
Resource: node01
Severity: Major
Indication Time: Mon Oct 07 13:19:08 2019
Suppress: false
Acknowledge: false
Probable Cause: One or more nodes are not connected to both cluster switches.
Possible Effect: If one cluster switch fails, "node01" might lose access to the cluster.
Corrective Actions: Ensure the switch "switch02" is connected to the node "node01".

Node: node01
Resource: node02
Severity: Major
Indication Time: Mon Oct 07 13:19:08 2019
Suppress: false
Acknowledge: false
Probable Cause: One or more nodes are not connected to both cluster switches.
Possible Effect: If one cluster switch fails, "node02" might lose access to the cluster.
Corrective Actions: Ensure the switch "switch01" is connected to the node "node02".

2 entries were displayed.

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support