跳转到主内容

NetApp_Insight_2020.png 

SwitchifisLDownwarn_alert 来自链路聚合 xx 的警报

Views:
3
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

状态信息

适用于

  • ONTAP 9.5P4
  • CN1610

问题

将 ONTAP 升级到 9.5p4 后、您会看到以下运行状况监视器警报:

natestdal0505-ff::*> system health alert show Node: netapp_node_01 Resource: Link Aggregate 10 Severity: Major Indication Time: Thu May 16 15:44:16 2019 Suppress: false Acknowledge: false Probable Cause: The cable used to connect switch "netapp_switch_01/ Link Aggregate 10" to the ISL port might be faulty. Possible Effect: Cluster redundancy might be lost. Corrective Actions: 1) Check whether the cable is fully inserted into the interface port on both ends. 2) Reconnect the ISL port using another cable. After reconnecting it, verify whether the link of the ISL port is up by executing the commands as per switch configuration guide or by checking whether the Link status LED is on.