无法访问单模式 VIF : VIF 状态报告单模式 VIF 已中断

Views:
15
Visibility:
Public
Votes:
0
Category:
data-ontap-7
Specialty:
network
Last Updated:

状态信息

适用于

Data ONTAP 7

问题

  • 二级 VIF 状态显示为“Broke
  • 在“vif status”输出中,“Strike Count”表示“10 of 10”:
    vifSingle: 2 links, transmit 'none', VIF Type 'single_mode' fail 'default'
         VIF Status    Broke   Addr_set
        up:
            member1: state up, since 08Apr2011 07:01:55 (3+01:49:14)
                    mediatype: auto-1000t-fd-up
                    flags: enabled
                    input packets 8818, input bytes 564352
                    output packets 110, output bytes 4620
                    output probe packets 70, input probe packets 0
                    strike count: 10 of 10
                    up indications 1, broken indications 0
                    drops (if) 0, drops (link) 0
                    indication: up at 08Apr2011 06:54:57
                            consecutive 266185, transitions 21
            member2: state up, since 08Apr2011 07:01:54 (3+01:49:15)
                    mediatype: Enabled virtual interface
                    flags: enabled favored
                    input packets 0, input bytes 0
                    output packets 233, output bytes 11548
                    output probe packets 140, input probe packets 0
                    strike count: 10 of 10
                    up indications 1, broken indications 0
                    drops (if) 0, drops (link) 0
                    indication: up at 08Apr2011 07:01:55
                            consecutive 266185, transitions 1