跳转到主内容

Unified Manager报告聚合已过量提交、如何在ONTAP中验证

Views:
28
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

适用场景

  • ONTAP 9.1及更高版本
  • OnCommand Unified Manager
  • OnCommand Insight
  • Active IQ Unified Manager

问题描述

  • 收到Unified Manager通知。

Risk          - Aggregate Overcommitted
Impact Area   - Protection
Severity      - Error
State         - New
Source        - Fas8200-01: AGG_01
Cluster Name  - Fas8200
Cluster FQDN  - 10.10.10.10
Trigger Condition - The overcommitted threshold set at 100% is breached. 121.07 TB (222.49%) of 54.42 TB is committed. 32.39 TB (59.52%) is used.
Description   - This alert will trigger when the aggregate has had more space allocated to volumes than the amount of usable space in the aggregate (or is close to using more space)

  • 计算过量承诺;
    • 类型DP 卷考虑卷的总大小
    • 键入RW volumes"뾼 싇 Maximum Autosize (如果 -autosize-mode 为off、则使用卷总大小)

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.