节点拥有属于集群中另一节点的聚合 - 在执行机头交换过程后
适用于
- ONTAP 9
问题
完成机头交换过程后 storage failover show
,将显示以下消息。
Cluster01::*> storage failover show
Takeover
Node Partner Possible State Description
-------------- -------------- -------- -------------------------------------
Cluster01-01 Cluster01-02 true Connected to Cluster01-02
Cluster01-02 Cluster01-01 true Connected to Cluster01-01.
Node owns aggregates belonging to another node in the cluster.
问题聚合显示了旧节点的序列。
cluster01-02 OLD sysID: 5xxxxxx68 cluster01-02 NEW sysID: 5xxxxxx98
cluster01::*> disk show -aggregate aggr_node2 -fields home,home-id,owner-id,owner
disk owner owner-id home home-id
------- ----------------- --------- ----------------- ---------
1.22.0 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68
1.22.1 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68
1.22.2 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68
1.22.3 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68
1.22.4 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68
1.22.5 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68
1.22.8 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68
1.22.9 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68
3.50.0 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68
3.50.1 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68
3.50.2 cluster01-02 5xxxxxx98 cluster01-01 5xxxxxx68