如果节点暂停并显示-power-off true且无错误输出、则节点将启动到LOADER
适用场景
ONTAP 9
问题描述
- 暂停两个节点至LOADER并确认两个电源状态均为OFF:
Cluster::> system halt -node * -inhibit-takeover true -skip-lif-migration-before-shutdown true -power-off true
Warning: Are you sure you want to power off node "Cluster-01"?
{y|n}: y
Warning: Are you sure you want to power off node "Cluster-02"?
{y|n}: y
2 entries were acted on.
BMC> system power status
Host power is off
- 节点重新启动后、即使启用了自动启动、它也会启动到LOADER、并且控制台日志没有错误输出:
LOADER-A> printenv
Variable Name Value
-------------------- --------------------------------------------------
ARCH X86_64
AUTOBOOT true
AUTOBOOT_FROM PRIMARY
- 控制台没有错误输出、节点可以通过从LOADER正常启动
boot_ontap
:
Wait BMC self-test result.
BMC self-test: OK.
UPI initialization.
CPU initialization.
Running full memory initialization.
CPU reset.
BIOS Version: 16.6
PEI start.
CPU PEI initialization.
Wait BMC self-test result.
BMC self-test: OK.
UPI initialization.
CPU initialization.
Running full memory initialization.
SPI FLASH: Primary BIOS
PEI end.
DXE start.
USB initialization.
PCI host bridge initialization.
CSM initialization.
PCI Bus initialization start.
BDS start.
Console output devices connect.
Version 2.20.1276. Copyright (C) 2021 American Megatrends, Inc.
BIOS Date: 09/15/2021 14:57:57 Ver: 16.6
Press <DEL> or <ESC> to enter setup.
Press <F7> to enter Boot Menu.
[System Information]
CPU = 2 Processors
DetectedCPU 0 : Intel(R) Xeon(R) Silver 4210 CPU @ 2.20GHz
Core : 10CPU 1 : Intel(R) Xeon(R) Silver 4210 CPU @ 2.20GHz
Core : 10Memory Size : 147456 MB
Ready to boot.
Boot Loader version 6.4.12
Copyright (C) 2000-2003 Broadcom Corporation.
Portions Copyright (C) 2002-2021 NetApp, Inc. All Rights Reserved.
ACPI RSDP Found at 0x6cc33000
LOADER-A> boot_ontap