跳转到主内容

由于同一个 Ifgrp 的端口之间的 LACP 密钥值不匹配, LACP Ifgrp 的成员端口将被标记为关闭

Views:
40
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core<a>1087318</a>
Last Updated:

适用场景

  • ONTAP 9.2 , 9.3 和 9.4
  • 链路聚合控制协议( LACP )接口组

问题描述

  • ifgrp show 将多模式 LACP 接口组中的一个或多个端口显示为关闭,表示它们不参与链路聚合
  • 成员端口已物理启动,但 ifgrp show显示为关闭

cluster1::> ifgrp show -node cluster1-01 -ifgrp a0a

Node: cluster1-01
Interface Group Name: a0a
Network Ports: e0c, e0d
Up Ports: e0d,
Down Ports: e0c

  • 此问题描述会在节点重新启动或链路驱动器后随机发生
  • node shell 命令 ifconfig -v 指示关闭的端口具有不同的滞后 ID :

cluster1::> node run -node cluster1-01 ifconfig -v

a0a : flags=8843<up , broadcast , running , sopolyast , multicas> metric 0 mtu 9000 options=6407bb<RXCSUM , TXCSUM , VLAN_mtu , vlan_csu HWM , TSO4 , TSO6 , LRO , VLAN_RXCSUM , RXCSUM_IPv6 , TXUM_IPv6

ether 02:a0:98:XX:YY:ZZ

lag id: [(8000,02-A0-98-11-22-33,0032,0000,0000),
(8000,AA-BB-CC-DD-EE-FF,0037,0000,0000)]

laggport: e0d flags=1c<ACTIVE,COLLECTING,DISTRIBUTING> state=3d<ACTIVITY,AGGREGATION,SYNC,COLLECTING,DISTRIBUTING>
[(8000,02-A0-98-11-22-33,0032,8000,0006),
(8000,AA-BB-CC-DD-EE-FF,0037,8000,00B9)]
input/output LACPDUs: 460 / 14099

laggport: e0c flags=18<COLLECTING,DISTRIBUTING> state=3d<ACTIVITY,AGGREGATION,SYNC,COLLECTING,DISTRIBUTING>
[(8000,02-A0-98-11-22-33,0033,8000,0007)
(8000,AA-BB-CC-DD-EE-FF,0037,8000,043A)]
input/output LACPDUs: 460 / 14099

  • 检查 ifconfig -v 输出中 LACP 端口的 LACPDU 中发送的系统 ID 和密钥值
    • 在上面的示例中,存储节点正在从其每个端口发送 systemID 02-A0-98-11-22-33 ,而交换机正在发送 systemID AA-BB-CC-DD-EE-FF
    • 与 systemID 同一行的是密钥值 0032,该值由交换机中的存储端口 e0d (与滞后 ID 相同)和 0033 (关闭 e0c 端口,因为它不匹配)和 0037 发送
  • 接口组(例如 a0a )配置在非默认 IP 空间中:

cluster1::> network port show -node cluster1-01 -port a0a -fields node,port,ipspace

cdot-vsim1-01 a0a test

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.