跳转到主内容

在较高的工作负载期间, FCP 速度较慢并发生 SRAM 转储

Views:
13
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san
Last Updated:

适用场景

  • ONTAP 9
  • SAN
  • Fibre Channel(光纤通道)(FC)

问题描述

  • 服务器使用 FCP LUN 的用户报告速度缓慢
  • 已计划作业或已计划工作负载正在环境中运行
  • 大规模部署 30 多台主机, 10 多个存储节点
  • qos volume latency show 表示网络的贡献最大 延迟
 cluster::> qos statistics volume latency show -vserver vserver -volume volume Workload ID Latency Network Cluster Data Disk QoS Max QoS Min NVRAM Cloud FlexCache SM Sync VA --------------- ------ ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- -total- - 24.15ms 22.90ms 15.00us 751.00us 480.00us 0ms 0ms 3.00us 0ms 0ms 0ms 0ms VOLUME 2178 1101.45ms 1101.34ms 6.00us 68.00us 36.00us 0ms 0ms 2.00us 0ms 0ms 0ms 0ms -total- - 21.09ms 19.98ms 11.00us 719.00us 375.00us 0ms 0ms 2.00us 0ms 0ms 0ms 0ms VOLUME 2178 995.61ms 995.50ms 6.00us 49.00us 50.00us 0ms 0ms 1.00us 0ms 0ms 0ms 0ms -total- - 26.80ms 25.16ms 12.00us 1206.00us 423.00us 0ms 0ms 3.00us 0ms 0ms 0ms 0ms VOLUME 2178 1107.57ms 1107.45ms 4.00us 69.00us 45.00us 0ms 0ms 2.00us 0ms 0ms 0ms 0ms -total- - 22.77ms 21.48ms 13.00us 893.00us 376.00us 0ms 0ms 3.00us 0ms 0ms 0ms 0ms VOLUME 2178 1486.07ms 1485.96ms 6.00us 58.00us 51.00us 0ms 0ms 1.00us 0ms 0ms 0ms 0ms -total- - 27.85ms 26.33ms 19.00us 1199.00us 299.00us 0ms 0ms 3.00us 0ms 0ms 0ms 0ms VOLUME 2178 1439.01ms 1438.94ms 3.00us 52.00us 9.00us 0ms 0ms 2.00us 0ms 0ms 0ms 0ms 
  • 多个存储节点上的多个卷会受到影响,而不会出现任何模式
  • 多个存储节点间歇性记录 SRAM 转储,端口重置,达到阈值和 / 或链路中断错误

Sun Feb 21 XX:XX:XX -0500 [NODE: fct_tpd_thread_15: scsitarget.fcp.dump:debug]: FCP target SRAM dump generated for adapter 10a, fct_tpd_check_hung_commands: Command termination hung. cmd:0xfffff817e09cdb70 (state=0xa, flags=0x2,ctio_sent=1/1, RecvExAddr=0x11e620, OX_ID=0x4439, RX_ID=0xffff, SID=0x2729e2)

Sun Feb 21 XX:XX:XX -0500 [NODE: fct_tpd_thread_15: scsitarget.fct.reset:notice]: Resetting Fibre Channel target adapter 10a.

Sun Feb 21 XX:XX:XX -0500 [NODE: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO TPD cmd alloc threshold reached handle:7 taskflags:128 Active commands:3891 threshold:3891

Sun Feb 21 XX:XX:XX -0500 [NODE: fct_tpd_work_thread_0: scsitarget.ispfct.linkBreak:error]: Link break detected on Fibre Channel target adapter 2a. Firmware status code status1 0x2, status2 0x7, and status4 0x0.

  • 客户端已使用轮循策略和正确配置 MPIO 所有优化的 IO 路径均处于活动状态(每个网络结构两个路径)
  • 低端口会丢弃交换机和 SFP 的增量 接收 / 传输未达到低阈值

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.