跳转到主内容

错误 - 从主机发出中止命令

Views:
31
Visibility:
Public
Votes:
0
Category:
data-ontap-7
Specialty:
san
Last Updated:

适用于

  • ONTAP 操作系统: 7 模式或集群模式 Data ONTAP (任何) 
  • 协议: FCP 和 iSCSI 
  • 主机操作系统:任何

问题

  • 在查看主机日志时,会显示一条或多条 " 中止的命令 " 或 " 中止的 I/O " 消息。根据主机操作系统和 HBA 型号 / 驱动程序,确切消息可能会有所不同,但错误通常如下所示:
  • 禁用出现错误的端口或接管可解决主机问题 错误和性能恢复正常 


Linux
Apr 16 09:13:34 Rhel01 kernel: qla2xxx 0000:08:00.0: scsi(3:1:30): Abort command issued -- 1 368ccd8 2002


VMware :
2017-11-29T23:30:12.469Z cpu0:33586)NMP: nmp_ThrottleLogForDevice:3333: Cmd 0x28 (0x43b658ca5680, 34912) to dev "naa.600a09803830374a7a2b49316b4a6433" on path "vmhba1:C0:T2:L1" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x3f 0xe. Act:EVAL

Or

2016-01-31T23:14:36.250Z cpu45:33200)<7>fnic : 1 :: Abort Cmd called FCID 0xb0020, LUN 0x7 TAG 74 flags 3
2016-01-31T23:14:36.250Z cpu6:33199)<7>fnic : 1 :: Abort Cmd called FCID 0xb0020, LUN 0x5 TAG 75 flags 3
2016-01-31T23:14:36.257Z cpu19:32787)<7>fnic : 1 :: abts cmpl recd. id 116 status FCPIO_SUCCESS
2016-01-31T23:14:36.257Z cpu45:33200)<7>fnic : 1 :: Returning from abort cmd type 2 SUCCESS
2016-01-31T23:14:36.257Z cpu19:32787)<7>fnic : 1 :: abts cmpl recd. id 117 status FCPIO_SUCCESS
2016-01-31T23:14:36.257Z cpu6:33199)<7>fnic : 1 :: Returning from abort cmd type 2 SUCCESS


Windows :
Information   10/24/2017 8:49:54 PM   ontapdsm   61117   None   IO error: SRB Status Aborted reported on LUN 18 on Path Id 01000001. The IO will be retried.
Warning     10/24/2017 8:49:46 PM   disk     153    None   The IO operation at logical block address 0x5f4ee4 for Disk 13 (PDO name: \Device\MPIODisk3) was retried.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.