问题描述

  • 一个或多个节点报告 ClusterSwitchConnectivity_Alert 事件和AutoSupport消息、例如:
HA Group Notification (Health Monitor process cshm: ClusterSwitchConnectivity_Alert[node_name]) ALERT
 
 
Call home for Health Monitor process cshm: ClusterSwitchConnectivity_Alert[node_name]
  • EMS消息:
[node_name: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchConnectivity_Alert, Alerting Resource = node_name raised by monitor ethernet-switch
  • 所有节点均可连接到NetApp Active IQ AutoSupport部分 DEVICE-DISCOVERY (或 network device-discovery show 通过ONTAP命令行界面)中的两个集群交换机。示例:

node_name   cdp   e0a   cluster-switch1(FOX1234ABCD)   Ethernet1/9
node_name   cdp   e0b   cluster-switch2(FOX5678EFGH)   Ethernet1/9
node_name   cdp   e0c   cluster-switch2(FOX5678EFGH)   Ethernet1/10
node_name   cdp   e0d   cluster-switch1(FOX1234ABCD)   Ethernet1/10

  • System healt alert 输出表示问题描述。示例:
::> system health alert show
               Node: node_name
           Resource: node_name
           Severity: Major
    Indication Time: Sun Dec 31 23:59:59 2023
           Suppress: false
        Acknowledge: false
     Probable Cause: One or more nodes are not connected to both cluster
                     switches.
    Possible Effect: If one cluster switch fails, node_name might lose
                     access to the cluster.
 Corrective Actions: Verify that the switch switch-01.
 
或 
 
::> system health alert show
         Node node_name
        Monitor ethernet-switch
       Alert ID ClusterSwitchConnectivity_Alert
   Alerting Resource node_name
       Subsystem Switch-Health
    Indication Time Wed Feb 14 09:47:57 2024
  Perceived Severity Major
    Probable Cause Configuration_error
      Description The ethernet switch, with the name "switch_name", is not connected to all of the nodes in the               cluster.
  Corrective Actions Verify that the switch "switch_name" is connected
            to the node "node_name" and that the switch's name has not
            been modified due to a change in the switch's link discovery protocol used for advertisements.
    Possible Effect If one cluster switch fails, "node_name" might lose access to the cluster.
      Acknowledge false
       Suppress false
        Policy ClusterSwitchConnectivity_Policy

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.