跳转到主内容

机头升级后,数据端口上出现 CRC 错误

Views:
14
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用于

  • AFF 系统
  • FAS 系统
  • 机头升级(也称为机头交换)
  • 数据端口上的 CRC 错误
  • ONTAP 9

问题

  • 在 ifstat 的网络接口卡( Network Interface Card , NIC )接收上显示 head 升级增量 CRC 错误后:
 

::>node run -node node_nameifstat 

 -- interface e5a (1 day, 2 hours, 8 minutes, 13 seconds) -- RECEIVE Total frames: 1204m | Frames/second: 12804 | Total bytes: 2921g Bytes/second: 31043k | Total errors: 1012 | Errors/minute: 1 Total discards: 8927k | Discards/minute: 5693 | Multi/broadcast: 147k Non-primary u/c: 0 | CRC errors: 780 | Long frames: 1 -- interface e5b (1 day, 2 hours, 8 minutes, 10 seconds) -- RECEIVE Total frames: 1609m | Frames/second: 17101 | Total bytes: 3317g Bytes/second: 35263k | Total errors: 965 | Errors/minute: 1 Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 187k Non-primary u/c: 0 | CRC errors: 832 | Long frames: 0 
  • 已查看交换机日志并确定未发现 CRC 错误
  • 已检查所有硬件(布线, SFP )

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support

 

  • 这篇文章对您有帮助吗?