跳转到主内容
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

EMS 日志中报告了广播域分区错误

Views:
87
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
network
Last Updated:

状态信息

适用场景

  • ONTAP 9
  • 以太网交换机    

问题描述

  • 在广播域的端口之间执行 l2ping 操作时, VIFMGR 可以记录以下 EMS 条目:
 [node1: vifmgr: vifmgr.bcastDomainPartition:alert]: Broadcast domain BD1 is partitioned into 2 groups on node node1. The different groups are: {E0M}, {A0A}. LIFs hosted on the ports in this broadcast domain may be at the risk of seeing connectivity issues. 
  • 运行命令 broadcast-domain show 将返回广播域的正确信息:

cluster::*> network port broadcast-domain show
IPspace Broadcast
Name    Domain Name Port                         
------- ----------- -----------------------------
Cluster Cluster
                    node1:e0d             
                    node1:e0f                                   
                    node2:e0d                                       
                    node2:e0f             
                                                      
Default BD1
                    node1:a0a             
                    node1:e0M             
                    node2:a0a             
                    node2:e0M 

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support