AutoSupport 发送失败
适用于
ONTAP 9
问题
- 节点无法使用 SMTP 发送 AutoSupport 。
Cluster::>autosupport history show
Seq Attempt Percent Last
Node Num Destination Status Count Complete Update
------------ ----- ----------- -------------------- -------- -------- --------
node01 1680 smtp transmission-failed 15 - 5/28/2020 02:20:53
- 使用“
system autosupport history show -seq-num 123 -instance
”命令查看特定顺序和Last Error
是Failed sending data to the peer
。
Cluster::> system autosupport history show -seq-num 1680 -instance
Node: node01
AutoSupport Sequence Number: 1680
Destination for This AutoSupport: smtp
Trigger Event: callhome.management.log
Time of Last Update: 5/28/2020 02:20:53
Status of Delivery: transmission-failed
Delivery Attempts: 15
AutoSupport Subject: MANAGEMENT_LOG
Delivery URI: mailto:autosupport@netapp.com
Last Error: Failed sending data to the peer
Time of Generation: 5/28/2020 00:01:51
AutoSupport Compressed Size: 131.4KB
Percent Complete: -
Rate of Upload: -
Time Remaining for Upload: 0s
AutoSupport Decompressed Size: 476.0KB
Total Collection Time (ms): 6257
- 可以在
unable to relay"
/etc/log/mlog/notifyd.log
日志中看到 " 错误。