In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

aggrp copy start 失败,并显示错误消息 "cannot init input, aborting "

Views:
16
Visibility:
Public
Votes:
0
Category:
data-ontap-8
Specialty:
core
Last Updated:

适用于

  • Data ONTAP 7
  • Data ONTAP 8 7-模式

问题

aggr copy start 运行时失败并报告Connection refused

 

filer2> aggr copy start -S filer1:aggr4 filer2:aggr13
This can be a long-running operation. Use Control - C (^C) to interrupt.
Copy Aggregate: aggr4 on machine filer1 to Aggregate: aggr13
filer1: Connection refused
AGGRCOPY: Could not connect to filer filer1.
AGGRCOPY: Cannot Init Input, aborting

 