启用FIPS后、出现Active IQ Unified Manager 502网关错误
适用场景
- ONTAP 9.9.1.1P3
- Active IQ Unified Manager
- FIPS
问题描述
启用FIPS后、Active IQ Unified Manager 停止与集群通信、从而导致出现以下错误:
<!-- Communication problem with the cluster: cluster-1, command: system-api-change-get-iter, error: 'Unexpected HTTP response: 502 Bad Gateway' on try 5 out of 5 -->
ONTAP 还会在MGWD中报告以下错误:
Tue May 03 2022 15:37:33 -04:00 [kern_mgwd:info:2312] dsmdb_get_imp_2() on process failed: 127.0.0.1{ffffffff|ffffffff} prog=536873536 server=servprocd: RPC: Timed out; netid=tcp fd=290 TO=25.0s TT=25.000s O=200b I=0b CN=2808267/1 VSID=-3 127.0.0.1:45193 <-> 127.0.0.1:935