适用场景

  • ONTAP 9.
  • CVO

问题描述

  • 由于出现错误、自动无中断升级(ANDU)已暂停
    • EMS或 cluster image show-update-progress 输出:
      Sat Jun 26 18:10:21 +0200 [cluster1-01: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the cluster has been paused due to the following reason: Node "MUM": Error: {Not all aggregates are online}, Action: {Ensure all aggregates are online..}. Node "MUM": Error: {Cluster is not in quorum.}, Action: {Use the (privilege: advanced) "cluster ring show" command to verify all replication unit details..}.
    • system node upgrade-revert show 输出:

・・・・・
Status Message: The upgrade aborted. Contact support personnel for the upgrade repair procedure.
・・・・・
Provisioning of consistency group failed on "create" during upgrade. Reason: Node "node1" on ring "Management" is offline.
Check the health of the cluster using the "cluster show" command. For further assistance, contact technical support.

  • 升级过程已暂停、因为无法进行存储恢复。
  • 集群管理应用程序(例如卷位置数据库(VLDB))在重新启动后未在节点上联机(可在高级命令 cluster ring show 输出中查看):

::> set advanced

::*> cluster ring show
Node    UnitName Epoch   DB Epoch DB Trnxs Master   Online
--------- -------- -------- -------- -------- --------- ---------
cluster1-01 mgmt   2     2     251    cluster1-01 master
cluster1-01 vldb   2     2     29     cluster1-01 master
cluster1-01 vifmgr 2     2     21     cluster1-01 master
cluster1-01 bcomd  2     2     7     cluster1-01 master
cluster1-01 crs   2     2     4     cluster1-01 master
cluster1-02 mgmt   2     2     251    cluster1-01 secondary
cluster1-02 vldb  0     36     1036078  -     offline
cluster1-02 vifmgr 2     2     21     cluster1-01 secondary
cluster1-02 bcomd  2     2     7     cluster1-01 secondary
cluster1-02 crs   2     2     4     cluster1-01 secondary

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.