跳转到主内容

7MTT :在过渡 CIFS 本地用户和组配置时解决防火墙问题

Views:
9
Visibility:
Public
Votes:
0
Category:
data-ontap-7
Specialty:
cifs
Last Updated:

状态信息

适用于

  • 7-模式过渡工具 
  • CIFS 本地用户和组

问题

运行预检查时, 7- 模式过渡工具( 7MTT )报告以下阻塞错误:

Error Code: 26000
Error Type: Blocking Error
Error Message: The HTTP port of the 7-Mode Transition Tool server is blocked by the firewall or HTTP port is not opened for                target SVM data LIFs. Therefore, 7-Mode Transition Tool cannot transition 7-Mode local users and groups                configurations to the following SVMs.
Corrective Action: Perform one of the following corrective actions and rerun the operation.
                   Make sure that the specified HTTP port is not blocked by the firewall and the HTTP port is opened to the                    target SVM data LIFs.
                   Ignore the transition of CIFS local users and groups configurations. Evaluate the impact before ignoring                    the transition of CIFS local users and groups. For more information about how to ignore the transition of                    CIFS local users and groups configurations, refer to the 7-Mode Transition Tool Guide.

 