跳转到主内容

定期 BMC 重置可能会在此事件中导致硬件故障 日志

Views:
10
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

适用于

SolidFire

问题

BMC 定期进行重置以防止 BMC 进程出现任何问题是正常的。

通常,我们只会看到消息 "Beginning BMC cold reset and setting new reset date" 。

有时会生成引用风扇 RPM 或 PSU 等的硬件故障。

这些事件纯属装饰,无需采取任何措施。事件日志显示 BMC 冷重置后的硬件故障。事件将在 60 秒内清除。

示例:

Event ID  Event Time                Type                       Message                                                       Service ID   Node ID   Drive ID    Details
xxxxx     2019-10-02 20:57:56  platformHardwareEvent  Beginning BMC cold reset and setting new reset date                  11        -        { "bmcResetDurationMinutes": 20160, "bmcResetDate": "2019-10-17T04:36:51" }
xxxxx     2019-10-02 20:57:09  platformHardwareEvent  Hardware fault detected                                                      11         -      "Hardware fault ID 2431 text=Fan1A RPM is failed or missing."
xxxxx     2019-10-02 20:57:09  platformHardwareEvent  Hardware fault detected                                                      11         -      "Hardware fault ID 2432 text=Fan1B RPM is failed or missing."
xxxxx     2019-10-02 20:57:09  platformHardwareEvent  Hardware fault detected                                                      11         -      "Hardware fault ID 2433 text=Fan2A RPM is failed or missing."
xxxxx     2019-10-02 20:57:09  platformHardwareEvent  Hardware fault detected                                                      11         -      "Hardware fault ID 2434 text=Fan2B RPM is failed or missing."
.........
xxxxx     2019-10-02 20:57:44  platformHardwareEvent  Hardware fault resolved                                                      11        -       "Hardware fault ID 2431"
xxxxx     2019-10-02 20:57:44  platformHardwareEvent  Hardware fault resolved                                                      11        -       "Hardware fault ID 2432"
xxxxx     2019-10-02 20:57:44  platformHardwareEvent  Hardware fault resolved                                                      11        -       "Hardware fault ID 2433"
xxxxx     2019-10-02 20:57:44  platformHardwareEvent  Hardware fault resolved                                                      11        -       "Hardware fault ID 2434"

Event ID   Event Time   Type   Message   Service ID   Node ID   Drive ID   Details
xxxxx   2020-10-16 11:51:10 platformHardwareEvent Beginning BMC cold reset and setting new reset date 4    3 - { "bmcResetDurationMinutes": 20160, "bmcResetDate": "2020-10-30T02:51:10" }

xxxxx   2020-10-16 11:52:31   platformHardwareEvent   Hardware event      3      "Power supply PS2 is not present."
xxxxx   2020-10-16 11:52:30   platformHardwareEvent   Hardware event      3      "Power supply PS1 is not present."

xxxxx   2020-10-16 11:53:36   platformHardwareEvent   Hardware event      3      "Power supply PS2 now present."
xxxxx   2020-10-16 11:53:36   platformHardwareEvent   Hardware event      3      "Power supply PS1 now present."

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support