In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

是否可以更改 NetApp HCI 系统上的 MTU 后安装

Views:
15
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
hci
Last Updated:

适用于

  • NetApp HCI
  • NetApp 部署引擎( NDE )
  • 最大传输单元 (MTU)

解答

在 NetApp 部署引擎( NDE )完成系统部署后、可以将所有 HCI 节点上的 MTU 大小设置更改为默认值 1500 ,但是 NDE 本身不支持该设置

如果将 MTU 大小设置更改为 1500 、 NDE 的 Easyscale 实用程序将无法向现有 VMware ESXi 或 NetApp Element 软件集群添加新的计算或存储节点。