跳转到主内容

H610s - BMC 自检失败

Views:
21
Visibility:
Public
Votes:
0
Category:
h-series
Specialty:
solidfire
Last Updated:

状态信息

适用场景

NetApp H610S

问题描述

  • 持久性集群故障:

BMC Self Test failed. This may impact IPMI based services and a BIOS/BMC update may be recommended.

  • 除了“ BMC Self Test Failed ”( BMC 自检失败)集群故障之外、还可能存在以下任何或所有情况:
    • 无法访问 BMC Web GUI
    • 节点脱机事件:
      • The SolidFire Application cannot communicate with node ID <#>
      • Node Offline nodeID=<#>
    • 无法 ping 或 SSH 到 BMC IP 地址
    • 与风扇、电源和系统传感器相关的持久集群故障。  示例
    • Fan1A RPM is failed or missing.
    • Error checking sensor for Fan1B RPM
    • Error checking sensor for Inlet Temp
    • Error checking sensor for Exhaust Temp
    • ipmitool 命令失败并出现以下错误:
    • Could not open device at /dev/ipmi0 or /dev/ipmi/0 or /dev/ipmidev/0: No such file or directory
    • Get SEL Info command failed: Invalid command
    • Error sending Chassis Status command: Invalid command
    • Get Channel Info command failed: Invalid command

 

 

 