问题

由于节点的底层基板管理控制器( Baseboard Management Controller , BMC )和 / 或 BMC 管理的内部硬件组件(风扇,电源等)出现问题,可能会在 Element 存储节点上生成各种与传感器相关的警报。

其中包括:

Error Code 错误详细信息 节点组件
风扇传感器

FanXX RPM is failed or missing

机箱风扇
sensorReadingFailed

sensorReadingFailed: IPMI diagnostics are currently unresponsive. Please contact support if this problem persists.

BMC
TempSensor

Error checking sensor for Exhaust Temp

Error checking sensor for Inlet Temp

温度传感器
nodeHardwareFault

Error checking sensor for Fan<#> RPM

 

风扇转数传感器
nodeHardwareFault

BMC Self Test failed. This may impact IPMI based services and a BIOS/BMC update may be recommended

 

BMC
nodeHardwareFault

 IPMI diagnostics are currently unresponsive. Please contact support if this problem persists.

BMC

各种传感器警报的关联影响范围从 none (特定 Element 版本和节点类型的误报警报)到影响节点集群性能不等。