In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

AutoSupport 消息: NodeHardwareFault

Views:
13
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

适用场景

  • NetApp Element 软件
  • SolidFire AFA
  • NetApp HCI
  • NetApp SF-Series
  • NetApp H-Series

问题描述

本文介绍运行 Element 软件的 NetApp 存储集群生成的各种警报类型以及相应的故障排除参考。

Error Code 错误详细信息 严重性 组件
内存使用阈值 系统内存非常低。Adding additional nodes or manually purging deleted volumes may help reduce memory usage. 错误 内存
内存使用阈值 系统内存不足。Adding additional nodes or manually purging deleted volumes may help reduce memory usage. 警告 内存
PowerSupplyError 电源的 PS2 输入缺失或超出范围。 警告 电源
PowerSupplyError 电源 PS1 输入缺失或超出范围。 警告 电源
硬件配置不匹配 插槽 <x> 中的驱动器应使用固件版本 <y> ,但使用的版本 <z> 不受支持 警告 固件( NIC )
nodeHardwareFault network_firmware_version_eth0 应为 =7.10.18-solidfire-5f3ccbc781d53 ,但应为 FFV7.10.18 bc 7.10.11 警告 固件( NIC )
nodeHardwareFault " 硬件故障 ID 826 text=network_firmware_version_eth2 应 = 3.2d 0x80000b4b 1.1767.0 ,但应为 3.2d 0x80000b4b 1.1681.0 " 警告 固件( NIC )
硬件配置不匹配 对于此节点类型,插槽 x 中的驱动器块驱动器大小( 1.0 GB ) /( 0.00) 不正确 - 预期为 xx 警告 驱动器(硬件)
TempSensor 温度传感器入口温度过高。 警告 温度传感器
硬件配置不匹配

不正确的 BIOS 设置 "CPU_cores_01" 应为 = <x> ,但为 <y>

警告 BIOS 设置
硬件配置不匹配 /var/log/sf-bios.info 中的解析失败应为 == false ,但为 true 警告 硬件配置

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support