跳转到主内容

将 H610s 添加到群集后出现“ Incorrect BIOS Setting ( BIOS 设置不正确)”警告

Views:
27
Visibility:
Public
Votes:
0
Category:
h-series
Specialty:
solidfire
Last Updated:

状态信息

适用于

  • NetApp H610 存储节点

问题

After adding a new or replacement node to a cluster, hardwareConfigMismatch 和nodeHardwareFault 警报 such as the following are logged:
 
  • Incorrect bios setting "CPU Stepping" should be == <0> but is <7>
  • Incorrect bios setting "System RAS Type" should be == <0> but is <6>
  • Incorrect bios setting "ME PTT Supported" should be == 0 but is 1
  • Incorrect bios setting "PCIE Port assigned to LAN" should be == <0> but is <5>
  • Incorrect bios setting "PCH Stepping" should be == <0> but is <53>
  • Incorrect bios setting "Gbe Region Valid" should be == [00]Disable but is [01]Enable
  • Incorrect bios setting "Anti Flash Wearout Supported" should be == 0 but is 1
  • Incorrect bios setting "IP Port" should be == <65535> but is <443>
  • Incorrect bios setting "FPK Port 3 Present" should be == 0 but is 1
  • Incorrect bios setting "FPK Port 2 Present" should be == 0 but is 1
  • Incorrect bios setting "FPK Port 1 Present" should be == 0 but is 1
  • Incorrect bios setting "FPK Port 0 Present" should be == 0 but is 1
  • Incorrect bios setting "Current IPMI over LAN" should be == [FF]Unknown but is [01]Enabled
  • NETWORK_FIRMWARE_VERSION_ETH1 should be == 14.20.1010 (MT_2420110034) but is 14.22.1002 (MT_2420110034)
  • NETWORK_FIRMWARE_VERSION_ETH0 should be == 14.20.1010 (MT_2420110034) but is 14.22.1002 (MT_2420110034)

 