SVM DR 重新同步无法在目标上应用源 SVM 配置
适用场景
- ONTAP 9
- SVM DR 重新同步
问题描述
运行 SVM DR 重新同步时应用程序出错:
Failed to apply the source Vserver configuration. Reason: Apply failed for Object: sis Method: baseline. Reason: Failed to modify efficiency configuration for volume "Dst_Vol" of Vserver "Dst_SVM": Cannot change the efficiency policy from "auto" because there is an active "auto" background efficiency operation on the volume. Use the "volume efficiency status" command to view the status of background efficiency operation on the volume. Use the "volume efficiency stop" command to issue stop on the running operation. If there is an active efficiency operation then use the "volume efficiency stop -all true -vserver "Dst_SVM" -volume "Dst_Vol" command to stop all efficiency operations on the volume "Dst_Vol".
Execute "snapmirror show -destination-vserver Dst_SVM -fields last-transfer-error,unhealthy-reason -expand" to check if the constituent volumes have encountered errors.