跳转到主内容

SVM DR重新同步失败、并显示错误"The volume's space guarantee cannot be changed"

Views:
7
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
dp<a>2008587065</a><a>翻译</a>
Last Updated:

适用场景

  • ONTAP 9
  • SVM 灾难恢复

问题描述

 

一个(或多个)卷的SVM DR传输失败、错误字符串为:
Failed to apply the source Vserver configuration. Reason: Apply failed for Object: volume Method: baseline. Reason: Unable to set volume attribute "space-guarantee" for volume "vol_name" on Vserver "dest_svm". Reason: The volume's space guarantee cannot be changed to "volume" while data-compaction is enabled and the volume contains compacted data. Use the command "volume efficiency undo -data-compaction true" to undo compaction, and then try the command again. Execute "snapmirror show -destination-vserver NASBCP2 -fields last-transfer-error,unhealthy-reason -expand" to check if the constituent volumes have encountered errors. Transfer failed

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.