在 MDV_CRS 卷丢失后, SVM-DR 停止工作
适用场景
- ONTAP 9.x
- SVM-DR
- CRS (配置复制服务)
问题描述
- SVM-DR更新失败
Last Transfer Error: Metadata volume is not available on cluster "source". Run "snapmirror config-replication status show" for more details.
- CRS未运行
Cluster1::> snapmirror config status show -instance
Enabled: true
Running: false
Recovery Steps: Verify that Vserver DR has been configured. If Vserver DR has already been configured successfully, check storage status below. If storage status is "ok", contact technical support for assistance.
Storage Status: warning
Storage In Use: Unavailable
Storage Remarks: Unable to free resources
Recovery Steps: Contact technical support for assistance.
Vserver Streams: ok
Recovery Steps: Follow the recovery steps associated with the "Running" field
- 当前卷字段为空、备用卷未确定、""
MDV_CRS_04848d35fcbf11e7afe900a098bdae56_A
标记在已放弃的卷下。
cluster1::*> debug cps storage-area-group show
Storage Area Group: config-replication-store
Use Mirrored Aggregate: false
Disallowed Aggregates: -
Auto-Repair: true
Auto-Recreate: true
Current Volume: -
Standby Volume: undetermined
Abandoned Volumes: MDV_CRS_04848d35fcbf11e7afe900a098bdae56_A
Volumes Under Repair: -
Problem Aggregates: -
Active Recreate Retry Count: 0
Standby Recreate Retry Count: 0