问题

  • SnapMirror 更新 / 重新同步失败,并显示:

Failed to apply the source Vserver configuration.

Reason: Failed to modify efficiency configuration for volume "<volume>" of Vserver "<SVM>": Compression cannot be disabled when inline compression or incompressible data detection is enabled on the volume. Disable inline compression and retry the command. If there are active SIS operations then use the "volume efficiency stop -all true -vserver * -volume *" command to stop all efficiency operations on all volumes in the cluster. Failed to apply the source Vserver configuration.

Reason: Apply failed for Object: sis Method: baseline.

Reason: Failed to modify efficiency configuration for volume "<Volume>" of Vserver "<SVM>": Compression cannot be disabled when inline compression or incompressible data detection is enabled on the volume. Disable inline compression and retry the command. If there are active SIS operations then use the "volume efficiency stop -all true -vserver * -volume *" command to stop all efficiency operations on all volumes in the cluster. 

 