跳转到主内容
If you missed the pre-registration for NetApp MS Azure AD B2C Go Live, when you log in, the new login prompt will offer the option to register. Please note that access to your NetApp data may take up to 1 hour. Need assistance? Complete this form and select “Registration Issue” as the Feedback Category. 

7MTT 过渡需要集群间 LIF

Views:
7
Visibility:
Public
Votes:
0
Category:
7-mode-transition-tool
Specialty:
network
Last Updated:

适用场景

7MTT ( 7- 模式过渡工具)

问题描述

  • TDP 允许使用:
    • 数据 LIF
    • 集群间 LIF
    • 管理 LIF 
  • 7MTT 要求使用:
    • 集群间 LIF
  • 尝试预检时, 7MTT 将出现错误
    • The following nodes in the cluster do not have any intercluster LIFs configured on them. One or more intercluster LIFs are required on the following nodes to perform SnapMirror data copy operations from the 7-Mode volumes to the clustered Data ONTAP volumes.
    • Create one or more intercluster LIFs on the affected nodes by using the following command: 'network interface create -vserver <node-vserver> -lif <lif-name> -role intercluster -home-node <node-name> -home-port <node-port> -address <ip-address> -netmask <netmask>'. After creating the intercluster LIFs, create the routing groups and routes for the LIFs. For more information about how to configure intercluster LIFs, refer to the Clustered Data ONTAP Network Management Guide.
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support