跳转到主内容

应用 MCCIP 配置后,交换机(重新)配置可能会导致 节点之间缺少通信

Views:
4
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用于

  • MetroCluster IP
  • Broadcom BES-53248 交换机
  • 初始安装

问题

根据安装文档,必须先将交换机设置为出厂默认值,更新和配置(应用了 RCF ),然后重新启动交换机,然后才能启动 MetroCluster IP 配置。 

如果在完成 MetroCluster IP 配置后出于任何原因配置交换机,则可能会导致 NV 内存通信中断。应观察到以下症状:

  • Storage failover interconnect error
  • NVRAM log not synchronized
  • Disk inventory not exchanged
  • 消息例如:nvmm.mirror.abortingcf.takeover.disabled

 