跳转到主内容

切回失败,原因是 " 切回期间磁盘留在后面 "

Views:
2
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • AFF-A800
  • 内部磁盘架

问题描述

  • 在重新调整测试期间,执行切回时会观察到以下情况:
Cluster_A (manual recovery required): Some disks were left behind during switchback. They are listed along with a reason for failure: 2.11.15 (no error)
If any of these disks are failed, replace them. Otherwise use the "metrocluster switchback" command again to return the disks to their original owner. Use the "storage disk show -dr-home-id !- -fields dr-home, container-type, aggregate" command for more details on the status of the left-behind disks.
 
  • 内部磁盘缺少配对节点 node_A_2 的路径
  • 运行以下命令时,不会报告缺少的路径:
 
Cluster_A::> storage disk show -disk 2.11.15
                  Disk: 2.11.15
        Container Type: shared
            Owner/Home: node_A_1 / node_A_1
   
Paths:
                                LUN  Initiator Side      
Controller         Initiator     ID  Switch Port         
------------------ ---------  -----  --------------------
node_A_1           0n            17  N/A                 
---------

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.