存储网桥 FC_port_X 处于脱机状态
适用场景
- 光纤 MetroCluster
- ATTO 7500N FibreBridge
- ATTO 7600N FibreBridge
问题描述
- ATTO 网桥上的一个 FC 端口报告脱机,并显示以下错误:
[hostname: dsbridge_admin: fc.bridge.fc.port.alert:alert]: Fibre Channel FibreBridge7500N Bridge ATTO_200000xxxxxxx4c0 S/N: FB7500Nxxxxxx WWN: 200000xxxxxxxxx FC Port FC_PORT1 offline.
[hostname: schmd: hm.alert.raised:alert]: Alert Id = StorageBridgePortDown_Alert , Alerting Resource = 210000xxxxxxxxx raised by monitor system-connect
[hostname: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: StorageBridgePortDown_Alert[210000xxxxxxxxx].
storage bridge show -fields fc-port-index-list,fc-port-oper-state-list shows one FC port as offline:
Example:
name fc-port-index-list fc-port-oper-state-list
----------------- ------------------ -----------------------
ATTO_200000xxxxxxx4c0 1,2 offline,online <<<< FC port 1 offline
ATTO_200000xxxxxxx480 1,2 online,online