跳转到主内容

由于未使用SAS端口、MetroCluster 中报告了StorageBridgePortDown_Alert

Views:
3
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2009347803</a>
Last Updated:

适用场景

  • ONTAP 9
  • 光纤 MetroCluster
  • ATTO FibreBridge
  • 带内监控

问题描述

  • 事件日志会报告以下警报:
[Node-01: schmd: hm.alert.raised:alert]: Alert Id = StorageBridgePortDown_Alert , Alerting Resource = 5001XXXXXXXXX884 raised by monitor system-connect
  • ATTO网桥SAS端口脱机、并报告以下错误:
ATTO_2000XXXXXXXXX880(2000XXXXXXXXX880):SAS_PORT_2 is Offline.
ATTO_2000XXXXXXXXX880(2000XXXXXXXXX880):SAS_PORT_3 is Offline.
  • 网桥运行状况因以下原因而降级:

Cluster1::> system health subsystem show
Subsystem      Health
----------------- ------------------
SAS-connect     ok
Environment     ok
Memory       ok
Service-Processor ok
Switch-Health    ok
CIFS-NDO      ok
Motherboard     ok
IO         ok
MetroCluster    ok
MetroCluster_Node ok
FHM-Switch      ok
FHM-Bridge     degraded
SAS-connect_Cluster ok
13 entries were displayed.

  • 这些脱机SAS端口已启用、但不用于任何连接。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.