在 MetroCluster 的头升级过程中、 SVM (虚拟服务器)停止

Views:
21
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

 

适用于

  • MetroCluster
  • ONTAP 9.5+
  • FC-VI 链路交叉布线
  • 包含以下顺序的 mgwd.log
    • has_remote_cluster_done_switchover was retried. Retry count : 9
    • has_remote_cluster_done_switchover failed with err = FCVI Interconnect might be down. For fabric configurations, use "storage switch add" to start monitoring the switches.

问题

  • 在磁头升级期间,所有 SVM 都将进入停止状态。
  • vserver start 命令失败并出现错误:

    Failed to determine if the remote cluster has done a switchover. Reason :
    Internal error occurred on node "ClusterA-02" in cluster "ClusterA".
    Details: (FCVI Interconnect might be down. For fabric configurations, use
    "storage switch add" to start monitoring the switches. Then run "storage switch
    show -port" to verify that the status of the used port is "online", and run
    "storage switch show -san-config" to verify that the fabric configuration
    (vsan/zone) is appropriate. For Stretch configurations, verify the FCVI
    cabling.). Are you sure you want to proceed? {y|n}: y

 

 

 

 