问题

"Running aggr show -r " 将显示类似于以下内容的输出:

集群 A

Aggregate ClusterA_aggr1 (online, raid_dp, mirror degraded) (block checksums)
  Plex /ClusterA_aggr1/plex0 (offline, failed, inactive)

  Plex /ClusterA_aggr1/plex1 (online, normal, active, pool1)
   RAID group /ClusterA_aggr1/plex1/rg0 (normal, block checksums)

    RAID Disk Device     HA     SHELF BAY   CHAN Pool Type  RPM   Used (MB/blks)    Phys (MB/blks)   
    --------- ------     --     ----- ---   ---- ---- ----  ---   --------------    --------------  
    dparity    4a.21.0    4a    21   0   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    parity     4a.21.1    4a    21   1   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.2    4a    21   2   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.3    4a    21   3   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.4    4a    21   4   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.5    4a    21   5   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.6    4a    21   6   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.7    4a    21   7   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.8    4a    21   8   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.9    4a    21   9   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.10   4a    21   10   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.11   4a    21   11   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.12   4a    21   12   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.13   4a    21   13   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.14   4a    21   14   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.15   4a    21   15   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.16   4a    21   16   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.17   4a    21   17   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.18   4a    21   18   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.19   4a    21   19   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.20   4a    21   20   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.21   4a    21   21   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 
    data      4a.21.22   4a    21   22   SA:A   1   SSD  N/A   762847/1562312192  763097/1562824368 

 

集群 B

Aggregate ClusterA_aggr1 (offline, raid_dp, mirror degraded) (block checksums)
  Plex /ClusterA_aggr1/plex0 (online, normal, active, pool0)
   RAID group /ClusterA_aggr1/plex0/rg0 (normal, block checksums)

    RAID Disk Device     HA     SHELF BAY   CHAN Pool Type  RPM   Used (MB/blks)    Phys (MB/blks)   
    --------- ------     --     ----- ---   ---- ---- ----  ---   --------------    -------------- 
    dparity   0a.11.0     0a      11   0   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    parity   0a.11.1     0a      11   1   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.2     0a      11   2   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.3     0a      11   3   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.4     0a      11   4   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.5     0a      11   5   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.6     0a      11   6   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.7     0a      11   7   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.8     0a      11   8   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.9     0a      11   9   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.10    0a      11   10   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.11    0a      11   11   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.12    0a      11   12   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.13    0a      11   13   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.14    0a      11   14   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.15    0a      11   15   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.16    0a      11   16   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.17    0a      11   17   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.18    0a      11   18   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.19    0a      11   19   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.20    0a      11   20   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.21    0a      11   21   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    data    0a.11.22    0a      11   22   SA:B   0   SSD  N/A   762847/1562312192  763097/1562824368
    
  Plex /ClusterA_aggr1/plex1 (offline, failed, inactive)

 