FCVI 端口上的物理链路已关闭
- Views:
- 17
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster<a>2008574610</a>
- Last Updated:
适用场景
- MetroCluster FC
- FC-VI 适配器
问题描述
- ONTAP 报告以下警报:
Cluster ::> system health alert show
Node: Node1
Resource: fcvi_device_3
Probable Cause: Physical link on port 5a is offline.
Possible Effect: DR protection of NVRAM mirror might be compromised.
- 事件日志显示物理链路已关闭:
[fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 5a.
[fcvi.qlgc.receive.error:error]: FC-VI adapter: Received bad frame on port 5a. Mailbox-1 = 4105, Mailbox-2 = 69. Resetting the port.
- FC-VI适配器的链路状态为已关闭:
Cluster::> metrocluster interconnect adapter show -node node1 -adapter fcvi_device_1 -instance
Adapter Name: fcvi_device_1
Adapter Type: FC-VI
Link Status: Down