In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

FCVI 端口上的物理链路已关闭

Views:
17
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2008574610</a>
Last Updated:

适用场景

  • MetroCluster FC
  • FC-VI 适配器

问题描述

  • ONTAP 报告以下警报:
Cluster ::> system health alert show
Node: Node1
Resource: fcvi_device_3
Probable Cause: Physical link on port 5a is offline.
Possible Effect: DR protection of NVRAM mirror might be compromised.
  • 事件日志显示物理链路已关闭:
[fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 5a.
[fcvi.qlgc.receive.error:error]: FC-VI adapter: Received bad frame on port 5a. Mailbox-1 = 4105, Mailbox-2 = 69. Resetting the port.
  • FC-VI适配器的链路状态为已关闭:
Cluster::> metrocluster interconnect adapter show -node node1 -adapter fcvi_device_1 -instance

Adapter Name: fcvi_device_1
Adapter Type: FC-VI
Link Status: Down

 