跳转到主内容
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

无法访问 ONTAP 调解器服务

Views:
17
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用于

  • MetroCluster IP
  • OTNAP9.
  • ONTAP 调解器

解答

查看此信息的价值:

无法从 MetroCluster 的一个或多个节点访问 ONTAP 调解器服务。在这种状态下不会发生自动计划外切换。

如何验证此检查? 

此检查将验证与 ONTAP 调解器服务的 iSCSI 连接。要验证是否发出以下命令:

ClusterA::*> storage iscsi-initiator show -label mediator
                                    Status
Node Type Label   Target Portal    Target Name            Admin/Op
---- ---- -------- ------------------ -------------------------------- --------
ClusterA-01
   mailbox
      mediator 10.1.1.1     iqn.2012-05.local:mailbox.target.6616cd3f-9ef1-11e9-aada-00a098ccf5d8:a05e1ffb-9ef1-11e9-8f68-00a0affeaffe:1 up/down
                                     
ClusterA-02
   mailbox
      mediator 10.1.1.1     iqn.2012-05.local:mailbox.target.6616cd3f-9ef1-11e9-aada-00a098ccf5d8:a05e1ffb-9ef1-11e9-8f68-00a0affeaffe:1 up/down
2 entries were displayed.

如果该条目显示为向下、则 ONTAP 尚未与 ONTAP 调解器服务建立连接(如上面的示例输出中所示)。

 

对于此活动 IQ 规则提供的信息,我该怎么办?  

验证 ONTAP 调解器服务是否正常运行。

其他信息

附加信息 _text

 

Scan to view the article on your device