节点报告已关闭或未使用的 FC 端口的 StorageFCAdapterFault_Alert
适用场景
- FAS/AFF
- 集群 ONTAP 8.3
- ONTAP 9 及更高版本
- MetroCluster
问题描述
- 每次重新启动后,节点都会针对已关闭的 FC 端口发送 AutoSupport 警报 StorageFCAdapterFault
Health Monitor process nchm: StorageFCAdapterFault_Alert[500##########]) ALERT
- 从 clustershell 可以看到警报,如下所示:
cluster::> system health alert show
Node: node-01
Resource: 4d
Severity: Major
Indication Time: Sat Aug 15 13:05:58 2020
Suppress: false
Acknowledge: false
Probable Cause: FC initiator adapter 4d is at fault.
Possible Effect: Resiliency of backend storage is compromised.
Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
2. Verify the operational status of the FC initiator
adapter by using the command "system node run -node
local -command storage show adapter".