跳转到主内容

MetroCluster 堆栈 ID 冲突

Views:
4
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • ONTAP 9
  • 光纤连接 MetroCluster

问题描述

  • 一个或多个节点在 stackmon.stack.id.conflict 事件日志中报告错误:
[Node-A: stackmon_thread: stackmon.stack.id.conflict:error]: Stack ID of the Shelf 30 (S/N SHFXXXXXXXXXX89) on channel Node101swb:8 cannot be agreed on by all the nodes in the cluster.
[Node-A: stackmon_thread: stackmon.stack.id.conflict:error]: Stack ID of the Shelf 70 (S/N SHFXXXXXXXXXX79) on channel Node100swa:8 cannot be agreed on by all the nodes in the cluster.  
  • 不同堆栈中磁盘架的堆栈ID报告相同的堆栈ID:

Cluster1::> storage shelf show -fields shelf, shelf-id, stack-id
node    shelf stack-id shelf-id
-------- ----- -------- --------
C1_N1     3.50  3        50     <<< Shelf in correct stack
C1_N1     3.51  3        51    <<< Shelf in correct stack
C1_N1     3.60  3        60     <<< Shelf in incorrect stack
C1_N1     3.61  3        61     <<< Shelf in incorrect stack
C1_N1     3.70  3        70     <<< Shelf in incorrect stack
C1_N1     3.71  3        71    <<< Shelf in incorrect stack

  • 由于堆栈ID不正确、可能会在事件日志中报告磁盘填充错误:
[Node-01: dsa_disc: ses.config.shelfPopError:error]: Disk shelf population on channel FC_switch_1:10 is 16. Reduce the number of disk shelves on this channel to 10 or fewer.
  • 每个堆栈的磁盘架数量不超过10个。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.