跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

由于SnapMirror\SnapVault策略错误、MetroCluster SVM可能不同步

Views:
18
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • MetroCluster
  • SnapMirror
  • SnapVault

问题描述

  • 由于SnapMirror\SnapVault策略错误、MetroCluster SVM可能无法同步。
  • 违规策略将在MetroCluster vserver show命令输出中命名。

Cluster1::*> metrocluster vserver show

Cluster  : NetApp_Cluster
                              Vserver  : VSERVER1
                      Partner Vserver  : VSERVER1-mc
                  Configuration State  : degraded
                        Stream Status  : operation-failed
                    Corrective Action  : Resynchronize the configuration using "metrocluster vserver resync" command. Contact technical support for assistance if configuration-state does not change to healthy.
                           Failed Row : Table Name: snapmirror_policy_ui, Operation: get, Fields: VSERVER1-mc vault_7day vault vserver-admin - 8 normal false always false - sv_vault 14 false 0 - - - - - - - false - - - - - - - - - - - b7e70ff0-4b2e-11ea-9f9d-00a0989db67c - unlimited -
                         Failed Reason : Apply failed for Object: snapmirror_policy_ui Method: baseline. Reason: Volume name not found for volume Data Set ID 1073743309 and volume Master Set ID 3236753984. (entry doesn't exist)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support