In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

MetroCluster 切换失败 - 内部错误。无法迁移虚拟服务器对等关系

Views:
17
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用于

  • ONTAP 9
  • 使用 SnapMirror 集群对等项的 MetroCluster
  • 切换
  • 切换 / 切换期间 SnapMirror 对等项关闭

问题

启动切换后,自动支持触发的标题为“ MetroCluster 切换失败”的字段。

metrocluster operation show 显示以下内容:

Operation: switchover
State: completed-with-manual-recovery-needed
Errors: <switchover_target_cluster> (manual recovery required): Internal error. Unable to migrate Vserver peer relationships. Reason: (Failed to communicate with peer cluster "<external_cluster>".). Contact technical support for assistance

事件日志中可能会报告以下内容:

[<node>: mgwd: cpeer.addr.stable.down:error]: Stable address <IP> of cluster <source/destination_cluster>, in IPspace <IPspace_name>, cannot be contacted.

此问题仅影响在成功切换之后的 SnapMirror/SnapVault 。

 