跳转到主内容

MetroCluster 切换失败 - 内部错误。无法迁移虚拟服务器对等关系

Views:
17
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用于

  • ONTAP 9
  • 使用 SnapMirror 集群对等项的 MetroCluster
  • 切换
  • 切换 / 切换期间 SnapMirror 对等项关闭

问题

启动切换后,自动支持触发的标题为“ MetroCluster 切换失败”的字段。

metrocluster operation show 显示以下内容:

Operation: switchover
State: completed-with-manual-recovery-needed
Errors: <switchover_target_cluster> (manual recovery required): Internal error. Unable to migrate Vserver peer relationships. Reason: (Failed to communicate with peer cluster "<external_cluster>".). Contact technical support for assistance

事件日志中可能会报告以下内容:

[<node>: mgwd: cpeer.addr.stable.down:error]: Stable address <IP> of cluster <source/destination_cluster>, in IPspace <IPspace_name>, cannot be contacted.

此问题仅影响在成功切换之后的 SnapMirror/SnapVault 。

 