跳转到主内容

ONTAP 中报告了FabricSwitchUnreachable_Alert

Views:
9
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2008900589.</a>
Last Updated:

适用场景

  • 光纤连接 MetroCluster
  • MetroCluster 后端网络结构交换机
  • SNMP 监控功能

问题描述

对于所有网络结构交换机、将清除并发出以下警报:

[node02: schmd: hm.alert.raised:alert]: Alert Id = FabricSwitchUnreachable_Alert , Alerting Resource = 1000XXXXXXXXXXd0 raised by monitor system-connect
[node02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: FabricSwitchUnreachable_Alert[1000XXXXXXXXXXd0].

::> system Health alAlert show

Node   XYZ-n2
Monitor   system-connect
Alert ID   FabricSwitchUnreachable_Alert
Alerting Resource   1000d81fcc5c4672
Subsystem   FHM-Switch
Indication Time   Sat Aug 13 09:05:52 2022
Perceived Severity   Major
Probable Cause   Connection_establishment_error
Description   "Brocade_XX.YY.ZZ.165" switch is not reachable over the management network.
Corrective Actions   1) Ensure that the node management LIF is up by using the command "network interface show".
   2) Ensure that the switch "Brocade_XX.YY.ZZ.165" is alive by using the command "network ping".
   3) Ensure that the switch is reachable over SNMP by checking its SNMP settings after logging into the switch.
Possible Effect   Switch "Brocade_XX.YY.ZZ.165" cannot be monitored for alerts.
Policy   FabricSwitchUnreachable_Policy
Additional Information              
               Switch: Brocade_XX.YY.ZZ.165
               Switch WWN: 1000d81fcc5c4672
               Component: Brocade_XX.YY.ZZ.165
               Error Type: switch-unreachable           
Alerting Resource Name   Brocade_XX.YY.ZZ.165

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.