跳转到主内容

在更换控制器期间、出现错误"发现名称相同但系统ID不同的重复filer_table条目"

Views:
67
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>1076865</a>
Last Updated:

适用场景

  • MetroCluster 双节点
  • ONTAP 9
  • 控制器更换
  • 未执行MetroCluster 修复

问题描述

在维护模式下重新分配磁盘后、将显示以下错误

May 15 20:31:42 [node1:diskown.ReassignFailed:error]: Disk reassign request failed. Reason: No disks found

示例:

*> disk reassign -s 1234567 -d 7654321

Disk ownership will be updated on all disks previously belonging to Filer with sysid 7654321.

May 15 20:31:40 [node1:diskown.duplicateSoftEntries:notice]: Found duplicate filer_table entries with same name node1 but different system ids (1234567,7654321)

Do you want to continue (y/n)? y

May 15 20:31:42 [node1:diskown.duplicateSoftEntries:notice]: Found duplicate filer_table entries with same name node1 but different system ids (1234567,7654321) Unable to complete disk reassign successfully (Error: No disks specified).

May 15 20:31:42 [node1:diskown.ReassignFailed:error]: Disk reassign request failed. Reason: No disks found

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.