更换控制器期间出现“发现名称相同但系统 ID 不同的文件管理器表条目重复”错误
适用于
- MetroCluster 2 节点
- ONTAP 9
- 控制器更换
- 未执行 MetroCluster 修复
问题
在维护模式下重新分配磁盘后,将出现以下错误
May 15 20:31:42 [node1:diskown.ReassignFailed:error]: Disk reassign request failed. Reason: No disks found
示例:
*> disk reassign -s 1234567 -d 7654321
Disk ownership will be updated on all disks previously belonging to Filer with sysid 7654321.
May 15 20:31:40 [node1:diskown.duplicateSoftEntries:notice]: Found duplicate filer_table entries with same name node1 but different system ids (1234567,7654321)
Do you want to continue (y/n)? y
May 15 20:31:42 [node1:diskown.duplicateSoftEntries:notice]: Found duplicate filer_table entries with same name node1 but different system ids (1234567,7654321) Unable to complete disk reassign successfully (Error: No disks specified).
May 15 20:31:42 [node1:diskown.ReassignFailed:error]: Disk reassign request failed. Reason: No disks found