跳转到主内容

在更换控制器期间、出现错误"发现名称相同但系统ID不同的重复filer_table条目"

Views:
56
Visibility:
Public
Votes:
0
Category:
metrocluster<a>1076865</a>
Specialty:
hw
Last Updated:

适用场景

  • MetroCluster 双节点
  • ONTAP 9
  • 控制器更换
  • 未执行MetroCluster 修复

问题描述

在维护模式下重新分配磁盘后、将显示以下错误

May 15 20:31:42 [node1:diskown.ReassignFailed:error]: Disk reassign request failed. Reason: No disks found

示例:

*> disk reassign -s 1234567 -d 7654321

Disk ownership will be updated on all disks previously belonging to Filer with sysid 7654321.

May 15 20:31:40 [node1:diskown.duplicateSoftEntries:notice]: Found duplicate filer_table entries with same name node1 but different system ids (1234567,7654321)

Do you want to continue (y/n)? y

May 15 20:31:42 [node1:diskown.duplicateSoftEntries:notice]: Found duplicate filer_table entries with same name node1 but different system ids (1234567,7654321) Unable to complete disk reassign successfully (Error: No disks specified).

May 15 20:31:42 [node1:diskown.ReassignFailed:error]: Disk reassign request failed. Reason: No disks found

 