In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

Brocade 缺陷 FOS-817953 是否会影响 MetroCluster 后端交换机?

Views:
21
Visibility:
Public
Votes:
0
Category:
not set
Specialty:
not set
Last Updated:

适用于

  • MetroCluster
  • Brocade

解答

使用命令可触发 FOS-817953 network fcp zone show。此命令不会查询 MetroCluster 后端交换机,而是仅查询前端 SAN 交换机。 

MetroCluster 后端配置中的配置详细信息是通过 SNMP 接收的,而不是network fcp zone show 通过命令接收的。 

MetroCluster 后端交换机不会受到 Brocade 缺陷 FOS-817953 的影响。