In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

在 MetroCluster 中,磁盘自动分配给错误的池和所有者

Views:
27
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用于

  • MetroCluster 

问题

新更换的驱动器自动分配给错误的池和所有者 

 Wed Apr 08 09:17:46 UTC [nodeA: dmgr_thread: raid.disk.inserted:info]: Disk 3b.125L517 Shelf 11 Bay 16 [NETAPP X438_S1633400AMD NA01] S/N [S20XXXX] UID [5002538A:758137E0:00000000:00000000:00000000:00000000] has been inserted into the system Wed Apr 08 09:17:46 UTC [nodeA: config_check: config.BadPoolAssign:error]: Disk 1.11.16 is in Pool0 and other disks on this loop/domain are in Pool1. Disks/interfaces need to be in separate pools for SyncMirror. 

 