跳转到主内容

由于"检测到软件中断异常"、ATTO网桥重新启动

Views:
2
Visibility:
Public
Votes:
2
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • ONTAP 9
  • MetroCluster FC 
  • ATTO 7500N FibreBridge

问题描述

  • ATTO网桥意外重新启动。为相同的生成AutoSupport :

HA Group Notification from node1 (Bridge Unexpected Reboot: FB7500XXXXXXX) ALERT

  • dumpeventlog allAutoSupport 日志中的网桥或bridge-all-event-log.tgz登录的事件显示以下错误:
5C2240 21:07:42 06/15/22 CRIT Software Interrupt Exception Detected (SWI) (001N)
5C2241 21:07:42 06/15/22 CRIT Instr Address   = 000385f0
5C2242 21:07:42 06/15/22 CRIT SWI Number     = 0x000000
5C2243 21:07:42 06/15/22 INFO Software Interrupt
5C2244 21:07:42 06/15/22 INFO 06/15/2022 21:07:42
5C2245 21:07:42 06/15/22 INFO ST[1ba13000-1ba14000] | FP[1ba13b8c] CPSR[60000193]
5C2246 21:07:42 06/15/22 INFO 0014bc7c<-00265578 | SP[1ba13b90] FP[1ba13bfc]
5C2247 21:07:42 06/15/22 INFO 0026544c<-00000584 | SP[1ba13c00] FP[1ba13c44]
5C2248 21:07:42 06/15/22 INFO 001d927c<-00d2844c | SP[1ba13c48] FP[1ba13f74]
5C2249 21:07:42 06/15/22 INFO 00d27f98<-00d0d3d0 | SP[1ba13f78] FP[1ba13fa4]
5C224A 21:07:42 06/15/22 INFO 00d0d33c<-00d13324 | SP[1ba13fa8] FP[1ba13fcc]
5C224B 21:07:42 06/15/22 INFO 00d130d0<-000417dc | SP[1ba13fd0] FP[1ba13ffc]
5C224C 21:07:42 06/15/22 INFO 00041680<-003eb310 | SP[1ba14000] FP[1ba14000]
5C224D 21:07:42 06/15/22 INFO Exception occurred. Possible redundant preceding log entries
5C224E 00:00:05 01/01/00 INFO Reset.  HW Code: Software Warm
5C224F 00:00:05 01/01/00 INFO Reset.  Reason: Critical Software Error Detected

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.